Aluminum wiring


Due to the rapid rise in the price of copper, aluminum wiring first appeared in homes around 1965, until about 1976. Note that these aluminum electrical wires are still accepted today and are often used for some installations due to its lower cost than copper :

  • Main electrical input

  • Power supply of the electric furnace

  • Cooker

Aluminum cables should be larger in diameter than copper. For example, a 12 AWG copper cable should be 10 AWG aluminum (larger). It is not the aluminum wiring that is problematic, but rather the connections as well as the type of outlet, switches or light fixtures that are connected to it.


Are aluminum wires problematic?

The aluminum wiring is not dangerous in itself if the installations have been done properly by a master electrician in accordance with the standard of practice. It is when the installation is inadequate with the use of sockets and switches not designed for this purpose as well as copper/aluminum connections that are not made adequately that the risks of overheating, electric arcs and fire are possible.

Electrical outlets, switches, and even twist-on connectors, which can be found in stores, are for the most part CU-certified (copper only). The costs of "CO/ ALR" certified units are much more expensive (designed to be connected to aluminum wiring). When an aluminum wire is connected to a CU-approved socket, the risk of galvanic corrosion due to contact with two different metals is present which may result in an electric arc and/or overheating and thus a risk of fire, over time.


What to do if I have aluminum wiring in my house?

This type of wiring has a sheath that is often white with the mention "AL" or "ALUMINUM" inscribed, but the sheath is sometimes green or blue. Contact Inspec-Pro Home Inspection to help check the electrical installations. Most insurers will systematically require this audit and some companies will simply refuse to insure for this type of wiring. It is best to check with your insurance company to ensure that coverage is adequate in the event of a claim.


How to correct inadequate installations?

COPALUM fittings or crimps -The first method is to replace all the aluminum wiring with copper cables, but this operation can be very expensive and often openings in the walls and ceilings will be necessary. On the other hand, during major renovations, it may be advantageous to replace everything that is accessible. -Another way is to use COPALUM fittings or crimps. This again requires a master electrician with a specialized tool to install the fittings. Redoing all the connections of a house with COPALUM crimp can cost about half the cost of replacing with copper wiring throughout the building.


Example CO/ALR electrical outlet -For sockets and switches, always use those approved "CO/ALR" which are designed to be connected directly to the aluminum cables. For multi-strand cables, the application of antioxidant paste is required to counter the risk of oxidation.


Signs of problems

  • Flashing lights

  • Presence of unusual static in the TV

  • Electric arcs coming from electrical sockets and switches

  • Switches or protective plates that feels hot to the touch

  • Circuit breakers that engage without good reason

  • Insulated sleeves blackened or melted near connections

  • Smell of burning or smoke present near switches, electrical sockets, junction boxes

  • Lights that burn quickly or shine more than normal

For more information contact Inspec-pro Home Inspection at 613.606.1901 or email us at inspec-pro@outlook.com.

10 views

Recent Posts

See All
20170804_091638
20170804_091824
20170804_092302
20170804_095545
20170420_100906
20170420_084959
20170420_071026
20170420_070525
20170420_080522
20170420_080613
20170414_160341
20170414_160217
20170414_141852
20170414_120059
20170414_120052
20170414_135545
20170414_141005
20170329_153300
20170329_124641
20170329_122640
20170329_141110
20170329_125633
20170320_164647
20170320_144618
20170320_150246
20170320_133355
20170320_140241
20170320_153326
20170201_124225
20170201_110122
20170201_104800
20170201_101959
20170201_102725
20170201_110016_001
20170201_130909
16387085_159984714504142_4465479758105272554_n
16388080_159984784504135_1416940839438664149_n
16427337_159984787837468_7820049585165436613_n
16388225_159984867837460_865419246506566848_n
16473914_159984914504122_3052500674011573928_n
16299090_159985077837439_5936936967625049672_n
16299349_159984984504115_4541639715084680005_n
16473344_159985087837438_8251368447405119593_n
Interactive Report
 Satisfaction Guaranteed
 Affordable Prices
Inspec-Pro Home Inspection
Rue Michel-Parizeau, Gatineau, Québec J9J 3X2
Phone: (613) 606-1901
In need of a home inspector?

© Copyright Inspec-Pro home inspection 

2020